SPECIFICATIONS FOR CONSTRUCTION:- In general To Have an idea about Building Specifications we are giving the details below.
Structure | : | Column foundation. Size of foundation – 4′6”x4′6”x6’ from existing ground level, tied with necessary plinth beams, with necessary reinforcement.(It vary from soil to soil so Soil test to be done first) |
Basement | : | Height of basement 2′ from existing ground level. |
Flooring | : | Vitrified tiles for All areas (2’x2’ normal colours) . |
Walls | : | External walls with 9″tk. Brick work and internal partition walls with 4 1/2″tk. brick work |
Plastering | : | External plastering finished roughly (sponge finish) and internal plastering finished smoothly. |
Lintels & Sunshades | : | Cut lintels and sunshades over window and door openings will be provided with suitable reinforcement. |
Roof slab | : | Roof with RCC 1:2:4 mix. Height of roof slab 10′0″ including roof slab thickness. Thickness of roof slab 4 1/2″ |
Doors | : | Main door with teak wood frame and teak wood panelled door, other doors with kongu wood frames and water proof Press doors with necessary hardware fittingslike lock and etc. Maindoor will be provided with nightlatch. |
Windows & Ventilators | : | Frames with Kongu wood frames and glazed shutters with padoak wood frames and 4mm pinhead glass. Grills at 1.5kg per sq.ft in 10mm square rod will be provided. |
Bedroom | : | One side loft and provision for cupboard below loft without wood works. |
Kitchen | : | Granite slab platform with stainless steel sink, glazed tiles (6″x8″ gujarat makefor 4’6″ height )above the platform, one tap connection will be provided at sink. |
Painting | : | Main door finished with varnish. All other doors, windows, grills will be painted with enamel paint |
Colour washing | : | Ceiling – three coats of whitewashWalls – Two coats of Exterior Emulsion painting over smooth putty and one coat of exterior primer. |
Toilets | : | All toilet will be provided with EWC (Normal colours only. Walls with glazed tiles (12″×24″) for 7′0″ height from floor level. Hot and cold water connection with tap and shower connection will be provided. |
Parapet wall | : | All round parapet wall upto 2′6″ height from roof level with 4 1/2″ brick wall with necessary 9″ pillars |
Electrical works
All wiring to be concealed and conduits in PVC with copper wires. The required electrical points shall be provided as noted below
Rooms | Light points | Fan point | Plug point | PowerPoint |
Hall/Dining | 3 | 2 | 3 | 1 |
Kitchen | 2 | 1 | 1 | 1 |
Bedroom | 2 | 1 | 1 | 1- For AC |
Toilet | 1 | – | – | 1-For Geyser |
Materials used:
Cement – Ramco, Coramandel, Birla Super And Ultratek
Bricks – Chamber bricks
Taps and Shower – Waterman or Westar
Electrical cables – Rachana, Anchor, Finolex
Switches and sockets – Modular
Switch box – Metal box
MS Reinforcement – with TMT Bars
For any sugestions reg your Residential plan or vasstu etc mail us we will give solutions for that.